Regulatory inspections of cabling work are conducted by the ACA in response to written complaints and randomly. Contracted auditors will conduct compliance audits of cabling work on a random basis.

Part 7 - Auditing registration documents. If the information is incorrect or if the registrar believes that there is a discrepancy in the information, the registrar must immediately notify the ACA of this and provide details of the error or discrepancy.

Schedule 1. Competency Requirements for Cabling Provider Rules For the purpose of paragraph 3. Part 1 Introduction Part 2 Restricted Cabling Requirements Part 3 Open Cabling Requirements Part 4 Lift Cabling Requirements The competency requirements for open, restricted and lift cabling types are detailed. Competency standards developed from the requirements in this document by the ITABs will be the basis for mandatory cabler registration under the Rules.

These competency standards will be submitted for endorsement to the National Training Framework Committee NTFC and placed on the national training register for formal recognition within the Australian vocational education and training system via the Telecommunications Training Package ICT Other national ITABs may either adopt these endorsed standards within their own training packages or formally demonstrate equivalence by mapping their existing standards to the competency requirements.

Restricted cabling work includes aerial and underground cabling work on private property. Typically the restricted type of customer cabling is confined to domestic premises but it may be applicable to some small business and commercial environments.

Generally this type of customer cabling is used to connect devices for the following range of applications: telecommunications phones, facsimile and answering machines , simple data and computer use, security alarm panels, and fire control panels.

The range of application, listed below, provides the conditions associated with the key elements for this type of cabling work and it specifies the basic knowledge and minimum expected cabler performance. Note: Jumperable distributors are not included in this requirement. Note: the documents above or their replacements apply. The cabler performance should preferably be assessed within the workplace environment, but suitably simulated workplace environments would be acceptable.

The following performance requirements must be demonstrated:. Cable installation including:. ACA cabling provider rules including:. Basic telephony including:. Open cabling work is any type of cabling work in which the customer cabling that is used terminates directly at the network boundary on a socket, network termination device, or a distributor. Open cabling work includes aerial and underground cabling work on private and public property.

Typically, open cabling work that terminates at distributors is associated with larger commercial and industry installations involving many lines, multi-pair cables, backbone cabling, multi-story buildings and complicated termination modules.

Generally open cabling work that terminates at distributors is used to connect devices for telecommunications phones and facsimile , data including video and multimedia, security and alarms, and fire protection. Note: The range of application and critical cabler performance requirements for the open cabling type includes that specified for the restricted type, however, the relevant information from restricted cabling has not been duplicated below.

Note: Cable trays may be galvanised steel or PVC. Perforated low or high sided, single or multi channel cable ducts may be closed, open, PVC, metal, single or multiple channel.

Note: Cable and topology may be chosen to suit a range of applications including analogue voice 3. Cable termination products including:. Cable conductor identification codes including:. Cable support systems including:. Cable types including:. Earthing systems including:.

Earth testing including:. Reading plans and specifications including:. Cable record systems including:. Switching systems awareness including:. Telecommunication hazard awareness including:. Basic Telephony including:. Lift cabling work is cabling work that is performed in relation to a lift that has been installed, or is to be installed.

The customer cabling that is used connects a cross connection point adjacent to the lift motor room, and the lift control cubicle within the lift motor room, and the lift cars. Generally this type of customer cabling is used to connect devices for telecommunications phones , data for video, audio and alarms. Note: The range of application and critical cabler performance requirements for the lift cabling type includes that specified for the restricted cabling type, however, the relevant information from restricted cabling has not been duplicated below.

The range of application, listed below, provides the conditions associated with the key elements for this category of cabling work and it specifies the basic knowledge and minimum expected cabler performance. Schedule 2. Deed in relation to Cabling Provider Registrar Obligations.

Cabling Provider Registrar Obligations. Operative Part Definitions 3. Interpretation 6. Scope of Deed 7. Term 7. Accreditation 7. Consequences of Accreditation 9. Fees 9. Reporting to the ACA Negation of Employment, Partnership and Agency Audit Registrar not sole registrar Services Development Plan Registrar Coordinating Committee Complaints Handling On-line Access Personal Information Intellectual Property Archives Act Compliance with Laws Compliance with Standards and Validation of Registrations Warranties Indemnity Liability Termination Consequences of Termination Cablers must notify ACRS of any change of contact You can read the full announcement here and view updated table of restrictions Members should read it in full.

In summary, in the eight LGAs of concern work can only be done in a person's home if: urgent to ensure the health, safety, or security of the premises or householdan emergencyfor the installation, maintenance and repairs of essential utilities, including a water, gas, electricity, internet, Subscribe to Newsletters. Need an Electrician? Requirements for registration In order to be registered cablers are required to complete modules or training competencies to show they are able to perform cabling work in accordance with the wiring rules.

From simple single-story homes to complex multi-level apartments or office buildings. Restricted : A restricted cabler registration does not allow the cabler to do anything more than a simple socket or network termination devices eg.

Lift : this type of registration is needed if the cabler is installing or maintaining communication ables in a lift or lift well. Better Call The Captain Book an Electrician Important: If you need an electrical job completed quickly, please phone us on 24 hours a day and talk to one of our staff.